Pulsation Flowmeter - Watermeter

 

  • Simple construction, same length for all diameters and pressures.
  • The mechanism that creates the pulses can be easily removed or fixed at the pipeline.
  • The propeller inside the water meter is only 10-15mm and therefore does not block the flow and does not create problems during the hammer shock phase.
  • The propeller position assures lond endurance for long lasting operation, due to the limitation of the axial forces and therefore minimal flow friction.
  • The traverse propeller requires limited force to rotate, which means that a simple propeller is adequate to guarantee quick and repeating rotation and long operation life.
  • The pulsation flowmeter can also measure speed since it indicates the instant quantity of the water flow.
  • Full bore without the slightest presure loss [loss diagram].
  • Light weight
  • It is not affected by surge waves.
  • long life due to the small weight of the propeller 5,5gr.
  • Simple and easily understood indications.
  • The pulses enable the the correct and accurate chlorination.
  • Transfers data to another location through wires or wireless.
  • Enables the operation of many pumps based on the consumption needs.
  • In case of exteranl interventions the flow meter measures based on time or can shut off the pump or the electrical valve.
  • The electronic system can be installed away form the flowmeter body.
  • Constant availability of spare parts and technical support.
  • Can bereprogrammed with new data.
  • High measurment accuracy with divergence 0,25% , especially when the installation is done according to the manufacturer's insturctions and conditions of proper function.
  • Both ways of flow dirction.
  • Water tight sensor having no contact with the water.
  • The head can be easily replaced in one minute.

Functionality

Installation position:

The flow meter works horizontally. For vertical installation consult the manufacturer to propose correct flow meter.

It is equipped with:

  • pulses output
  • frequencly output
  • output 4-20mA
  • digital clock

Technical review

Sizes DN50 up to DN1200
Pressure PN10, PN16, PN25, PN40
Materials Body  Ductile Iron GGG DIN1693/EN1563
Steel GS 45-St 37

More attributes

DIMENSIONS

DIMENSIONS                        LENGTH

DN50 -DN100                    215mm

DN125 and above                  300mm